Fischer Assay is a standardized laboratory test for determining the oil yield from oil shale to be expected from a conventional shale oil extraction. A 100 gram oil shale sample crushed to <2.38 mm is heated in a small aluminum retort to 500 °C (930 °F) at a rate of 12°C/min (22°F/min), and held at that temperature for 40 minutes.[1] The distilled vapors of oil, gas, and water are passed through a condenser and cooled with ice water into a graduated centrifuge tube. The oil yields achieved by other technologies are often reported as a percentage of the Fischer Assay oil yield.

The original Fischer Assay test was developed in the early low temperature coal retorting research by Franz Joseph Emil Fischer and Hans Schrader.[2] It was adapted for evaluating oil shale yields in 1949 by K. E. Stanfield and I. C. Frost.[3]

See also

References

fr:Méthode de titrage de Fischer