Pipeline Internal Corrosion
Two types of corrosion can occur in oil and gas pipeline systems when CO2 and H2S are present in the hydrocarbon fluid: sweet corrosion and sour corrosion. Sweet corrosion occurs in systems containing only carbon dioxide or a trace of hydrogen sulfide (H2S partial pressure < 0.05 psi). Sour corrosion occurs in systems containing hydrogen sulfide above a partial pressure of 0.05 psia and carbon dioxide.
When corrosion products are not deposited on the steel surface, very high corrosion rates of several millimeters per year can occur. This “worst case” corrosion is the easiest type to study and reproduce in the laboratory. When CO2 dominates the corrosivity, the corrosion rate can be reduced substantially under conditions where iron carbonate can precipitate on the
steel surface and form a dense and protective corrosion product film. This occurs more easily at high temperatures or high pH values in the water phase. When H2S is present in addition to CO2, iron sulfide films are formed rather than iron carbonate, and protective films can be formed at lower temperature, since iron sulfide precipitates much easier than iron
carbonate. Localized corrosion with very high corrosion rates can occur when the corrosion product film does not give sufficient protection, and this is the most feared type of corrosion attack in oil and gas pipelines.
Contents
Sweet Corrosion: Carbon Dioxide
CO2 is composed of one atom of carbon with two atoms of oxygen. It is a corrosive compound found in natural gas, crude oil, and condensate and produced water. It is one of the most common environments in the oil field industry where corrosion occurs. CO2 corrosion is enhanced in the presence of both oxygen and organic acids, which can act to dissolve iron carbonate scale and prevent further scaling.
Carbon dioxide is a weak acidic gas and becomes corrosive when dissolved in water. However, CO2 must hydrate to carbonic acid H2CO3, which is a relatively slow process, before it becomes acidic. Carbonic acid causes a reduction in the pH of water and results in corrosion when it comes in contact with steel. Areas where CO2 corrosion is most common include flowing wells, gas condensate wells, areas where water condenses, tanks filled with CO2, saturated produced water, and pipelines, which are generally corroded at a slower rate because of lower temperatures and pressures. CO2 corrosion is enhanced in the presence of both oxygen and organic acids, which can act to dissolve iron carbonate scale and prevent further scaling. The maximum concentration of dissolved CO2 in water is 800 ppm.
When CO2 is present, the most common forms of corrosion include uniform corrosion, pitting corrosion, wormhole attack, galvanic ringworm corrosion, heat-affected corrosion, mesa attack, raindrop corrosion, erosion corrosion, and corrosion fatigue. The presence of carbon dioxide usually means no H2 embrittlement. CO2 corrosion rates are greater than the effect of carbonic acid alone. Corrosion rates in a CO2 system can reach very high levels (thousands of mils per year), but it can be effectively inhibited. Velocity effects are very important in the CO2 system; turbulence is often a critical factor in pushing a sweet system into a corrosive regime. This is because it either prevents formation or removes a protective iron carbonate (siderite) scale.
CO2 corrosion products include iron carbonate (siderite, FeCO3), iron oxide, and magnetite. Corrosion product colors may be green, tan, or brown to black. This can be protective under certain conditions. Scale itself can be soluble. Conditions favoring the formation of a protective scale are elevated temperatures, increased pH as occurs in bicarbonate-bearing
waters, and lack of turbulence, so that the scale film is left in place. Turbulence is often the critical factor in the production or retention of a protective iron carbonate film. Iron carbonate is not conductive. Therefore, galvanic corrosion cannot occur. Thus, corrosion occurs where the protective iron carbonate film is not present and is fairly uniform over the
exposed metal. Crevice and pitting corrosion occur when carbonate acid is formed. Carbon dioxide can also cause embrittlement, resulting in stress corrosion cracking.
Corrosion Predictions
CO2 corrosion of carbon steel used in oil production and transportation, when liquid water is present, is influenced by a large number of parameters, some of which are listed below:
- Temperature;
- CO2 partial pressure;
- Flow (flow regime and velocity);
- pH;
- Concentration of dissolved corrosion product (FeCO3);
- Concentration of acetic acid;
- Water wetting;
- Metal microstructure (welds);
- Metal prehistory
The detailed influence of these parameters is still poorly understood and some of them are closely linked to each other. A small change in one of them may influence the corrosion rate considerably. Various prediction models have been developed and are used by different companies. Among them are the deWaard et al. model (Shell), CORMED (Elf Aquitaine), LIPUCOR (Total), and a new electrochemically based model developed at IFE. Due to the complexity of the various corrosion controlling mechanisms involved and a built-in conservatism, the corrosion models often overpredict the corrosion rate of carbon steel. The Shell model for CO2 corrosion ismost commonly used in the oil/gas industry. The model is mainly based on the deWaard equation published in 1991.
Starting from a “worst case” corrosion rate prediction, the model applies correction factors to quantify the influence of environmental parameters and corrosion product scale formed under various conditions. However, the first version of the model was published in 1975, and it has been revised several times, in order to make it less conservative by including
new knowledge and information.
The original formula of de Waard and Milliams implied certain assumptions that necessitated the application of correction factors for the influence of environmental parameters and for the corrosion product scale formed under various conditions. CO2 corrosion rates in pipelines made of carbon steel may be evaluated using industry accepted equations that preferably combine contributions from flow-independent kinetics of the corrosion reaction at the metal surface, with the contribution from the flow-dependent mass transfer of dissolved CO2.
The corrosion rate calculated from the original formula with its correction factors is independent of the liquid velocity. To account for the effect of flow, a new model was proposed that takes the effect of mass transport and fluid velocity into account by means of a so-called resistance model:
where Vcr is the corrosion rate in mm/year, Vr is the flow-independent contribution, denoted as the reaction rate, and Vm is the flow-dependent contribution, denoted as the mass transfer rate. In multiphase turbulent pipeline flow, Vm depends on the velocity and the thickness of the liquid film, whereas Vr depends on the temperature, CO2 pressure, and pH.
Comparison of CO2 Corrosion Models
The corrosion caused by the presence of CO2 represents the greatest risk to the integrity of carbon steel equipment in a production environment and is more common than damage related to fatigue, erosion, or stress corrosion cracking. NORSOK, Shell, and other companies and organizations have developed models to predict the corrosion degradation.
NORSOK’s standard M-506 can be used to calculate the CO2 corrosion rate, which is an empirical model for carbon steel in water containing CO2 at different temperatures, pH, CO2 fugacity and wall shear stress. The NORSOK model covers only the corrosion rate calculation where CO2 is the corrosive agent. It does not include additional effects ofother constituents, which may influence the corrosivity (e.g. H2S), which commonly appears in the production flowlines. If such a constituent is present, the effect must be evaluated separately. None of the de Waard models includes the H2S effect.
System Temperature
Temperature has an effect on the formation of protective film. At lower temperatures the corrosion product can be easily removed by flowing liquid. At higher temperatures the film becomes more protective and less easily washed away. Further increases in temperature result in a lower corrosion rate and the corrosion rate goes through a maximum. This temperature is referred to as the scaling temperature. At temperatures exceeding the scaling temperature, corrosion rates tend to decrease to close to zero, according to de Waard. Tests by IFE Norway revealed that the corrosion rate is still
increasing when the design temperature is beyond the scaling temperature. where the total pressure is 48 bara and the pH is equal to 4.2. The corrosion rate increases with increasing temperature, when the temperature is lower than the scaling temperature.H2S
H2S can depress pH when it is dissolved in a CO2 aqueous solution. The presence of H2S in CO2/brine systems can reduce the corrosion rate of steel when compared to the corrosion rate under conditions without H2S at temperatures of less than 80 C, due to the formation of a metastable iron sulfide film. At higher temperatures the combination of H2S and chlorides will produce higher corrosion rates than just CO2/brine system because a protective film is not formed.
H2S at levels below the NACE criteria for sulfide stress corrosion cracking (per the MR0175 NACE publication reduces general metal loss rates but can promote pitting. The pitting proceeds at a rate determined by the CO2 partial pressure; therefore, CO2-based models are still applicable at low levels of H2S. Where the H2S concentration is greater than or equal to the CO2 value, or greater than 1 mol%, the corrosion mechanism may not be controlled by CO2 and, therefore, CO2-based models may not be applicable.
pH
pH affects the corrosion rate by affecting the reaction rate of cathodes and anodes and, therefore, the formation of corrosion products. The contamination of a CO2 solution with corrosion products reduces the corrosion rate. pH has a dominant effect on the formation of corrosion films due to its effect on the solubility of ferrous carbonate. An increase in pH slows down the cathodic reduction of Hþ.
Inhibitors and Chemical Additives
The impingement of sand particles can destroy the inhibitor film and, therefore, reduce inhibitor efficiency. Inhibitors also perform poorly in lowvelocity lines particularly if the fluids contain solids such as wax, scale, or sand. Under such circumstances, deposits inevitably form at the 6 o’clock position, preventing the inhibitor from reaching the metal surface. Flow velocities below approximately 1.0 m/s should be avoided if inhibitors are expected to provide satisfactory protection; this will be critical in lines containing solids.
Inhibitor Efficiency versus Inhibitor Availability
When inhibitors are applied, there are two ways to describe the extent to which an inhibitor reduces the corrosion rate: inhibitor efficiency (IE) and inhibitor availability (IA). A value of 95% for IE is commonly used. However, inhibitors are unlikely to be constantly effective throughout the design life. For instance, increased inhibitor dosage or better chemicals will increase the inhibitor concentration. It may be assumed that the inhibited corrosion rate is unrelated to the uninhibited corrosivity of the system and all systems can be inhibited to 0.1 mm/year. The corrosion inhibitor is not available 100% of the time and therefore corrosion will proceed at the uninhibited rate for some periods. inhibitors that are able to protect the steel to a corrosion rate CRmit (typically 0.1 mm/year) regardless of the uninhibited corrosion rate CRunmit, taking into consideration the percentage of time IA the inhibitor is available.Chemical Additives
Glycol (or methanol) is often used as a hydrate preventer on a recycled basis. If glycol is used without the addition of a corrosion inhibitor, there will be some benefit from the glycol. De Waard has produced a glycol correction factor. However, if glycol and inhibitor are both used, little additional benefit will be realized from the glycol and it should be ignored for design purpose. Methanol is batch injected during start-up until flowline temperatures rise above the hydrate formation region and during extended shutdown.
Single-Phase Flow Velocity
Single-phase flow refers to a flow with only one component, normally oil, gas, or water, through a porous media. Fluid flow influences corrosion by affecting mass transfer and by mechanical removal of solid corrosion products. The flow velocity used in the corrosion model is identified as the true water velocity.Multiphase Flow
Multiphase flow refers to the simultaneous flow of more than one fluid phase through a porous media. Most oil wells ultimately produce both oil and gas from the formation and often also produce water. Consequently, multiphase flow is common in oil wells. Multiphase flow in a pipeline is usually studied by the flow regime and corresponding flow rate. Because of the various hydrodynamics and the corresponding turbulence, multiphase flow will further influence the internal corrosion rate, which is significantly different from that of single-phase flow in a pipeline in terms of corrosion.
Water Cut
The term water cut refers to the ratio of water produced compared to the volume of total liquid produced. CO2 corrosion is mainly caused by water coming in contact with the steel surface. The severity of the CO2 corrosion is proportional to the time during which the steel surface is wetted by the water phase. Thus, the water cut is an important factor influencing the corrosion rate. However, the effect of the water cut cannot be separated from the flow velocity and the flow regime.
Free-Span Effect
Pipeline spanning can occur on a rough seabed or a seabed subjected to scour. The evaluation of the allowable free-span length should be considered in order to avoid excessive yielding and fatigue. The localized reduction of wall thickness influences the strength capacity of the pipeline and, therefore, the allowable free-span length.Sour Corrosion: Hydrogen Sulfide
Hydrogen sulfide is a flammable and poisonous gas. It occurs naturally in some groundwater. It is formed from decomposing underground deposits of organic matter such as decaying plant material. It is found in deep or shallow wells and also can enter surface water through springs, although it quickly escapes to the atmosphere. Hydrogen sulfide often is present in wells drilled in shale or sandstone, or near coal or peat deposits or oil fields. Hydrogen sulfide gas produces an offensive “rotten egg” or “sulfur water” odor and taste in water. In some cases, the odor may be noticeable only when the water is initially turned on or when hot water is run.
Heat forces the gas into the air, which may cause the odor to be especially offensive in a shower. Occasionally, a hot water heater is a source of hydrogen sulfide odor. The magnesium corrosion control rod present in many hot water heaters can chemically reduce naturally occurring sulfates to hydrogen sulfide. Hydrogen sulfide (H2S) occurs in approximately 40% of all wells. Wells with large amounts of H2S are usually labeled sour; however, wells with only 10 ppm or above can also be labeled sour. Partial pressures above 0.05 psi H2S are considered corrosive. The amount of H2S appears to increase as the well ages. H2S combines with water to form sulfuric acid (H2SO4), a strongly corrosive acid. Corrosion due to H2SO4 is often referred to as sour corrosion. Because hydrogen sulfide combines easily with water, damage to stock tanks below water levels can be severe.
Water with hydrogen sulfide alone does not cause disease. However, hydrogen sulfide forms a weak acid when dissolved in water. Therefore, it is a source of hydrogen ions and is corrosive. It can act as a catalyst in the absorption of atomic hydrogen in steel, promoting sulfide stress cracking (SSC) in high-strength steels. Polysulfides and sulfanes (free acid forms of polysulfides) can form when hydrogen sulfide reacts with elemental sulfur. The corrosion products are iron sulfides and hydrogen. Iron sulfide forms a scale at low temperatures and can act as a barrier to slow corrosion.
The absence of chloride salts strongly promotes this condition and the absence of oxygen is absolutely essential. At higher temperatures the scale is cathodic in relation to the casing and galvanic corrosion starts. The chloride forms a layer of iron chloride, which is acidic and prevents the formation of an FeS layer directly on the corroding steel, enabling the anodic reaction to continue. Hydrogen produced in the reaction may lead to hydrogen embrittlement. A nuisance associated with hydrogen sulfide includes its corrosiveness to metals such as iron, steel, copper, and brass. It can tarnish
silverware and discolor copper and brass utensils.
Internal Coatings
The primary reason for applying internal coatings is to reduce friction, which enhances flow efficiency. Besides, the application of internal coatings can improve corrosion protection, precommissioning operations, and pigging operations. Increased efficiency is achieved through lowering the internal surface roughness since the pipe friction factor decreases with a decrease in surface roughness. In actual pipeline operation the improved flow efficiency will be observed as a reduction in pressure drop across the pipeline.
The presence of free water in the system is one cause of corrosion in an inner pipeline. An effective coating system will provide an effective barrier against corrosion attack. The required frequency of pigging is significantly reduced with a coated pipeline. The wear on pig disks is substantially reduced due to the pipe’s smoother surface. The choice of a coating is dictated by both environmental conditions and the service requirements of the line. The major generic types of coatings used for internal linings include epoxies, urethanes, and phenolics. Epoxybased materials are commonly used internal coatings because of their broad range of desirable properties, which include sufficient hardness, water resistance, flexibility, chemical resistance, and excellent adhesion.
Internal Corrosion Inhibitors
Corrosion inhibitors are chemicals that can effectively reduce the corrosion rate of the metal exposed to the corrosive environment when added in small concentration. They normally work by adsorbing themselves to form a film on the metallic surface [6]. Inhibitors are normally distributed from a solution or by dispersion. They reduce the corrosion process by either:
- Increasing the anodic or cathodic polarization behavior;
- Reducing the movement or diffusion of ions to the metallic surface;
- Increasing the electrical resistance of the metallic surface. Inhibitors can be generally classified as follows:
- Passivating inhibitors;
- Cathodic inhibitors;
- Precipitation inhibitors;
- Organic inhibitors;
- Volatile corrosion inhibitors.
The key to selection of an inhibitor is to know the system and anticipate the potential problems in the system. The system conditions include water composition (such as salinity, ions, and pH), fluid composition (percentage water versus hydrocarbon), flow rates, temperature, and pressure. Application of the inhibitors can be accomplished by batch treatments, formation squeezes, continuous injections, or a slug between two pigs. Inhibitor efficiency can be defined as: Inhibitor efficiency ð%Þ ¼ 100 ðCRuninhibited CRinhibitedÞ=CRuninhibited where CRuninhibited is the corrosion rate of the uninhibited system and CRinhibited is the corrosion rate of the inhibited system. Typically the inhibitor efficiency increases with an increase in inhibitor concentration.
References
[1] C. de Waard, U. Lotz, D.E. Milliams, Predictive Model for CO2 Corrosion Engineering in Wet Natural Gas Pipelines, Corrosion vol. 47 (no12) (1991), pp. 976–985.
[2] Norwegian Technology Standards Institution, CO2 Corrosion Rate Calculation Model, NORSOK Standard No. M-506, 2005.
[3] R. Nyborg, Controlling Internal Corrosion in Oil and Gas Pipelines, Oil and Gas Review(Issue 2) (2005).
[4] A. Dugstad, L. Lunde, K. Videm, Parametric Study of CO2 Corrosion of Carbon Steel, Corrosion/94, NACE International, paper no.14, Houston, TX, 1994.
[5] National Association of Corrosion Engineers, Metals for Sulfide Stress Cracking and Stress Corrosion Cracking Resistance in Soul Oilfield Environments, NACE MR 0175 (December 2003).
[6] www.corrosion-doctors.org/Inhibitors/lesson11.htm. [7] D.A. Jones, Principles and Prevention of Corrosion, first ed., McMillan, New York, 1992, pp. 437–445.
[8] E.D. Sunde, Earth Conduction Effects in Transaction Systems, Dover Publishing, New York, 1968, pp. 70–73.
[9] Det Norsk Veritas, Cathodic Protection Design, DNV RP B401, 1993.
[10] W.H. Hartt, X. Zhang,W. Chu, Issues Associated with Expiration of Galvanic Anodes on Marine Structures, Paper 04093, Corrosion (2004).
[11] K. Bethune, W.H. Hartt, A Novel Approach to Cathodic Protection Design for Marine Pipelines: Part II -Applicability of the Slope Parameter Method, presented at Corrosion, paper no.00674, 2000.
[12] International Organization for Standardization, Pipeline Cathodic Protection-Part 2:Cathodic Protection of Offshore Pipelines, ISO/TC 67/SC 2 NP 14489, Washington, D.C, 1993.
[13] DeepStar, Flow Assurance Design Guideline, 2001.